How to install the pulverized spray ball valve?

Users are aware of spray pulverized coal ball valve is an application extremely harsh environmental conditions ball valve, the installation is correct or not directly affect the life of the spray valve pulverized, then how the installation is correct? Following is a brief introduction for everyone:
1)First removing pulverized spray ball valve cover flange ends on both sides, rinsed clean under the valve is fully open.
2)Pneumatic ball valve and electric spray pulverized coal powder spray valve signal should be required prior to installation (electric or gas) in the test machine (to prevent vibration due to transport, affecting performance), after passing the line installation (refer electric wiring actuator wiring diagram).
3) Preparation and front pipe connections, to be washed and cleaned of impurities remaining in the pipeline (of these substances may damage the seats and balls).
4) During the installation, please does not use spray valve actuator pulverized coal as part of the lifting of the lifting points to avoid damage to the actuator and accessories.
5) This type ball valve should be installed in the pipeline horizontally or vertically.
6) The installation of the pipeline near the falls or external force cannot have the phenomenon, you can use duct work or support to eliminate the deviation from the pipeline.
7)And pipe connections, please use the specified torque cross locking flange bolts for the ball valve.
Should you want to know more about ball valve from Reliable China valve manufacturer, please visit www.reliavalve.com or email us via sales@reliavalve.com.